• Supervise and assign daily tasks to a team of technicians to carry out the daily operations.
• Monitor and coordinate monthly machinery servicing and maintenance works and keep proper records.
• Maintain and monitor the condition of Chiller, Evaporator, Condenser’ Shell & Tube Temperature, Motor Efficiency and Calculate Voltage Unbalance, Current Unbalance and Winding Temperature.
• Conduct monthly services for AHU, FCU’ filters, Chilled water pump, Condenser Water Pump, Strainers, Two-way actuator valve, Motorize valve.
• Servicing Motor and Belt tension, Drainage system and Exhaust System.
• Dosing a chemical for Chilled Water Piping, Condenser Water Piping with Aqua Clean 265 for Corrosion and Bio Clean 500 for Bacteria.
• Maintain and service upon Fire System including as Smoke Detectors, Sounders, Manual Call Points, Fire Module, Emergency Exit Light, Addressable System and Smoke Stop Curtain.
• Participating Fire Drill with MFSD and Other Respective Departments.
• Inspection and testing insulation resistance for Lightning arrester, Earthing system and TL box for 6 Monthly Maintenance.
• Calculate a new extension of power usage for breaker size, wire size and electrical fixtures and cooling load calculation.
• Check Wiring connection, Wiring temperature, Tiding nuts and Measure Voltage, Current Rating and Megger Test for Distribution Board and Switch Board.
• Design & Consult upon their design plan’ KEAD, KFAD, P&S, Gas Detection System for F&B Shop.
• Compute and Reduce the load due to the energy saving plan.
มิถุนายน 2562 ถึง กรกฎาคม 2565
Maintenance Engineer
Ar Yu International Hospital
Yangon, Myanmar.
สำหรับสมาชิกเท่านั้น
• Recorded a daily checklist for Feeders, Generator Condition, Automatic Water System for Ground and Roof Tank, Chiller Plant System and RO Water System.
• Tested Fire Electric Pump, Fire Diesel Pump by auto or manual operation mode Quarterly Preventive Maintenance Schedule.
• Checked and Inspected the pressure of Fire Hose Reel, Wet Riser & Fire Sprinkler Line by Monthly Checklist.
• Serviced ACMV System for OT, MRI Temp, Pressure & Humidity.
• Tested and maintained DOL, Star-Delta and Auto Transfer System for tube well, underground tank and roof tank.
• Participated & Coordinated a project in Positive & Negative Pressure Room during Covid-19 Period.
• Installed and Collaborated 1000 kVA Generator and Cable for 7th Storey Building in Ar Yu Compound.
เมษายน 2561 ถึง พฤษภาคม 2562
ACMV Engineer
Yangon International Airport
Yangon, Myanmar.
สำหรับสมาชิกเท่านั้น
• Listed require materials, daily schedule about work and manage to general workers.
• Checked and Operated for CHW Pumps, CDW Pumps, AHU and FCU
• Preventive Maintained for AHU, FCU and Pre-Cooled Units’ Filters and Drainage Line.
• Clean and Service of Cooling Tower’ Hot Water Basin, Cold Water Basin, Fills, Fan’ Belts and Float Balls.
• Cleaned process for Cooling Tower & Chemical Dosing for Chiller System.
• Measured the control panel for fuse, breaker, pilot lamp, incoming voltage and ampere.
• Reported to team manager weekly incident and further process.
• Regular maintained for the water treatment system and centers' drain pipe system.